Monday, 17 March 2014

Don't Let Your Domestic Hot Water Storage Tank Get To This Point!

Corroded Domestic Hot Water Storage Tank

I hate this situation...no matter how much effort we put into educating people concerning the importance of preventative maintenance on Hot Water Storage Tanks...there will always be people we have not reached or people who have chosen not to heed our call.


The other day I came across a tank and found that I was to late, the tank has a leak on the back dish.  This Domestic Hot Water Storage tank is 5' x 15' in size and is located in a basement boiler room, it's so large that the room would have been built around it.  Unfortunately now the customer is at a place where they are going to have to spend money to see how much they have to spend.

A preventative maintenance plan would have prevented this leak from taking place and would have saved this customer unwanted downtimes and now huge capital cost associated with repairs and replacement.  In the past we have seen 2 weeks plus in downtimes and repair/replacement costs exceed $100,000.00.  This could have been prevented at a fraction of the cost and with a planned shut down.

The solution is simple folks:
  1. Anode Replacement - Have your 'Sacraficial Magnesium Anodes' replaced every 1 to 3 years depending on the quality of water.  This will protect all the unlined areas of your tank.
  2. Tank Reline - Have your Domestic Hot Water Storage Tank Relined every 8 to 12 years with Pre-Krete T-61 which is CSA approved for use in potable water.
By completing these 2 services, a large DHWST with a manway should outlast the life of building.

Call Provincial Tank Lining and Inspections for more information and/or to discuss a preventative maintenance plan for the tanks in your portfolio.

Regards,

Jason

Jason Rusnak
Director of Business Development
Provincial Tank Lining and Inspections Inc.
C: 519.387.2635
www.ProvTank.com

Monday, 28 October 2013

The Face of Corrosion

Provincial Tank Lining and Inspections Inc. - Visual Internal Inspection


I was perusing through our inventory of pictures and came across an image that scared me.  I know I've displayed some pretty horrifying images of Domestic Hot Water Tanks in the past but nothing...nothing comes close to this image.

The Face of Corrosion

Provincial Tank Lining and Inspections Inc. - The Face of Corrosion
The Face of Corrosion


Do you see it? Look to the very center of the image.  This image has not been doctored.  The face appears to be almost "Grinch" like, devious.

I believe this image encapsulates the very essence of corrosion...evil and destructive.

In our industry the "Face of Corrosion" equals unwanted downtimes and unwanted expenses, not to mention all the peripheral related effects.

Provincial Tank Lining and Inspections provides a $349.00 +taxes Visual Internal Assessment to give you peace of mind in knowing that the "Face of Corrosion" is nowhere to be found in your DHWST.

We've designed the 'Visual Internal Inspection' to give you the tools needed to make an educated decision regarding the next step in required maintenance for your Domestic Hot Water Storage Tank.

Our 'Visual Internal Inspection' Includes:
  • Manway Cover Assessment
  • Visual Anode Assessment
  • Visual Interior Lining Assessment
  • Visual Assessment of Interior Inlets and Outlets
  • Visual Assessment of Exterior Inlets and Outlets
  • Digital Report with Pictures
  • Free Gasket
  • Peace of Mind


Call Provincial Tank Lining and Inspections Inc. for more information or to book your 'Visual Internal Inspections' today.

Regards,

Jason

Jason Rusnak
Director of Business Development
Provincial Tank Lining and Inspections Inc.
C: 519.387.2635
www.ProvTank.com

Friday, 26 July 2013

Heavily Corroded Domestic Hot Water Storage Tank.

Hot Water Storage Tank


Heavily Corroded Domestic Hot Water Storage Tank.
Heavily Corroded Domestic Hot Water Storage Tank

This is an image of an unmaintained, heavily corroded DHWST.  This is bad news.  When a tank reaches this stage it's likely that it can't be saved.  At this point you'll be spending money to see how much you're going to have to spend.

So what's the next step?

1)  This first step required is a UT (Ultrasonic Thickness) Test to determine the integrity of the vessel.

2)  Results of the UT Test determine the next step:
  •  UT Test Pass - Tank can be prepped, relined and you're good for another 12-15 years with regular anode replacement.
  • UT Test Fail - A Certified Pressure Vessel Authority (ie. BCSA, TSSA) would be required to determine the next step.
3)  A Few Options:
  • Tank is condemned and tank replacement is required.
  • Tank requires certified welders to weld buildups in specific areas to  meet requirements and be approved for future service.
  • Tank requires certified welders to weld in new sheets of metal in specific areas to  meet requirements and be approved for future service.
4)  If welding has been performed a Certified Pressure Vessel Authority will be required to sign off on the welding.

5)  Once the welding has been approved, a Hydrostatic Pressure Test is required to ensure the integrity of the welds, making sure there are no leaks.

6)  Once the Hydrostatic Pressure Test has been performed, passed, and signed off by a certified Authority, the Domestic Hot Water Storage Tank can now be prepped, relined and you're good for another 12-15 years with regular anode replacement.

Tip:  Don't let your tank get to this point.

Be proactive with these 3 simple steps:
  • Perform regular anode replacement every 1-3 years depending on the quality of water.
  • Reline you tank every 12-15 years.
  • Repeat